NextSDS Docs

Stop, above 400

A Fine & Kinney score above 400. Stop activities under current conditions.

Stop activities under current conditions.

A score above 400 means the work cannot continue the way it is done now. Stop the activity until measures bring the score down.

What it asks of you

  • Stop the activity with this product at this workplace under the current conditions.
  • Decide how the work can be done differently: another product, a closed process, or far less exposure.
  • Only restart once a reassessment gives a lower band.

How to bring it down

At this level a single measure is often not enough. Work through all three factors:

  • Probability: enclose the process or combine technical controls with personal protection.
  • Exposure: do the task less often and for a shorter time.
  • Effect: replace the product with one that carries fewer or milder H-statements.

Example

A product with H330 and H314 has an effect of 40 + 15 = 55. It is used for up to 4 hours a day, High exposure (6), with Inadequate protection (6):

55 × 6 × 6 = 1,980, Stop.

ChangeScoreBand
Adequate controls (0.51)168.3High
Closed system (0.2)66Medium
Closed system (0.2) and Occasional exposure (1.5)16.5Low